Schneider Electric SCADA Expert ClearSCADA Cross-site Scripting

Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.

Solusi CVE

Schneider Electric advises all ClearSCADA users to take steps to secure the interfaces to the ClearSCADA system. The ClearSCADA database security configuration should be reviewed and updated to limit all system access to authorized users only. The access permissions of existing users should be reduced to only those required by their role (e.g., removing any higher level System Administration privileges from Operations or Engineering users), and specific accounts should be created with appropriate permissions for performing System Administration tasks. Existing ClearSCADA customers using WebX can protect their system from cross-site scripting attacks by disabling the “Allow database shutdown via WebX” option within the ClearSCADA Server Configuration utility. Existing ClearSCADA customers should take measures to ensure their system does not grant any system access until users have supplied a valid username and password. Schneider Electric has corrected the default user security permissions; however, upgrading an existing vulnerable installation to a new version will not affect existing configured database security permissions. Therefore, the measures suggested here are strongly recommended for all users. Schneider Electric has corrected these vulnerabilities in the following service packs: * ClearSCADA 2010 R3.2, Released October 2014, and * SCADA Expert ClearSCADA 2014 R1.1, Released October 2014. If asset owners wish to upgrade to a new ClearSCADA Service Pack, please contact the local Schneider Electric office for the latest software version for ClearSCADA; alternatively, these new versions are available for direct download from the Schneider Electric web site. To update their license (not required when upgrading to a service pack of the same version), asset owners are required to complete and submit an online form, which is available here: http://resourcecenter.controlmicrosystems.com/display/CS/StruxureWare+SCADA+Expert+ClearSCADA+Update... http://resourcecenter.controlmicrosystems.com/display/CS/StruxureWare+SCADA+Expert+ClearSCADA+Update+Request+Form New Service packs for ClearSCADA are available for download here: http://resourcecenter.controlmicrosystems.com/display/CS/SCADA+Expert+ClearSCADA+Support General instructions on how to upgrade the ClearSCADA license (if required) are available here: http://resourcecenter.controlmicrosystems.com/display/CS/Updating+Your+ClearSCADA+License

Informasi CVE

Kelemahan Terkait

CWE-ID Nama Kelemahan Sumber
CWE-79 Improper Neutralization of Input During Web Page Generation
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

Metrik

Metrik Skor Tingkat keparahan CVSS Vektor Sumber
V2 4.9 AV:N/AC:H/Au:S/C:N/I:N/A:C
V2 3.5 AV:N/AC:M/Au:S/C:N/I:P/A:N nvd@nist.gov

EPSS

EPSS adalah model penilaian yang memprediksi kemungkinan suatu kerentanan dieksploitasi.

Skor EPSS

Model EPSS menghasilkan skor probabilitas antara 0 dan 1 (0 hingga 100%). Semakin tinggi skor, semakin besar probabilitas bahwa suatu kerentanan akan dieksploitasi.

Persentil EPSS

Persentil digunakan untuk meranking CVE berdasarkan skor EPSS mereka. Misalnya, CVE di persentil ke-95 berdasarkan skor EPSS-nya lebih mungkin dieksploitasi daripada 95% CVE lainnya. Dengan demikian, persentil digunakan untuk membandingkan skor EPSS suatu CVE dengan CVE lainnya.

Produk yang Disebutkan

Konfigurasi 0

Aveva>>Clearscada >> Version 2010

Aveva>>Clearscada >> Version 2010

Aveva>>Clearscada >> Version 2013

Aveva>>Clearscada >> Version 2013

Aveva>>Clearscada >> Version 2013

Aveva>>Clearscada >> Version 2013

Aveva>>Clearscada >> Version 2013

Schneider-electric>>Scada_expert_clearscada >> Version 2013

Schneider-electric>>Scada_expert_clearscada >> Version 2014

Referensi

https://ics-cert.us-cert.gov/advisories/ICSA-14-259-01
Tags : Third Party Advisory, US Government Resource