CVE の説明

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.

CVE の情報

関連する弱点

CWE-ID 弱点名 出典
CWE-94 Improper Control of Generation of Code
The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.

メトリクス

メトリクス スコア 深刻度 CVSS ベクター 出典
V2 5 AV:N/AC:L/Au:N/C:N/I:P/A:N nvd@nist.gov

EPSS

EPSSは脆弱性が悪用される可能性を予測するスコアリングモデルです。

EPSSスコア

EPSSモデルは0から1(0〜100%)の確率スコアを算出します。スコアが高いほど、脆弱性が悪用される可能性が高いことを示します。

EPSSパーセンタイル

パーセンタイルはCVEをEPSSスコアで順位付けするために使用されます。例えば、EPSSスコアで95パーセンタイルにあるCVEは、他の95%のCVEよりも悪用される可能性が高いことを意味します。パーセンタイルはCVEのEPSSスコアを他のCVEと比較するために使用されます。

関連製品

構成 0

Siemens>>Wincc_flexible >> Version 2004

Siemens>>Wincc_flexible >> Version 2005

Siemens>>Wincc_flexible >> Version 2007

Siemens>>Wincc_flexible >> Version 2008

Siemens>>Wincc_flexible >> Version 2008

Siemens>>Wincc_flexible >> Version 2008

構成 0

Siemens>>Wincc >> Version ~まで(含む) v11

Siemens>>Wincc >> Version v11

Siemens>>Wincc >> Version v11

構成 0

Siemens>>Simatic_hmi_panels >> Version comfort_panels

Siemens>>Simatic_hmi_panels >> Version mobile_panels

Siemens>>Simatic_hmi_panels >> Version mp

Siemens>>Simatic_hmi_panels >> Version op

Siemens>>Simatic_hmi_panels >> Version tp

構成 0

Siemens>>Wincc_runtime_advanced >> Version v11

構成 0

Siemens>>Wincc_flexible_runtime >> Version *

参考資料