CVE-2011-4509:詳細資料

CVE-2011-4509

1.2%V4
2012-02-03
20h00 +00:00
A01-Broken Access Control
Network
2024-09-17
01h26 +00:00
指定 CVE 通知
掌握特定 CVE 的任何變更。
管理通知

CVE 描述

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.

CVE 資訊

相關弱點

CWE-ID 弱點名稱 來源
CWE-264 Category : Permissions, Privileges, and Access Controls
Weaknesses in this category are related to the management of permissions, privileges, and other security features that are used to perform access control.

指標

指標 評分 嚴重程度 CVSS 向量 來源
V2 10 AV:N/AC:L/Au:N/C:C/I:C/A:C nvd@nist.gov

EPSS

EPSS 是一種預測漏洞被利用可能性的評分模型。

EPSS 評分

EPSS 模型產生介於 0 到 1(0% 到 100%)之間的概率分數。分數越高,漏洞被利用的概率越大。

EPSS 百分位數

百分位數用於根據 EPSS 分數對 CVE 進行排名。例如,EPSS 評分在第 95 百分位的 CVE 比 95% 的其他 CVE 更有可能被利用。因此,百分位數用於比較某 CVE 的 EPSS 分數與其他 CVE 的相對位置。

相關產品

設定 0

Siemens>>Wincc_flexible >> Version 2004

Siemens>>Wincc_flexible >> Version 2005

Siemens>>Wincc_flexible >> Version 2007

Siemens>>Wincc_flexible >> Version 2008

設定 0

Siemens>>Wincc >> Version v11

設定 0

Siemens>>Simatic_hmi_panels >> Version comfort_panels

Siemens>>Simatic_hmi_panels >> Version mobile_panels

Siemens>>Simatic_hmi_panels >> Version mp

Siemens>>Simatic_hmi_panels >> Version op

Siemens>>Simatic_hmi_panels >> Version tp

設定 0

Siemens>>Wincc_runtime_advanced >> Version v11

設定 0

Siemens>>Wincc_flexible_runtime >> Version *

參考資料