CVE-2014-2370:詳細資料

CVE-2014-2370

0.56%V4
2014-07-24
14h00 +00:00
Cross-site Scripting
A03-Injection
Network
2025-10-06
18h01 +00:00
指定 CVE 通知
掌握特定 CVE 的任何變更。
管理通知

CVE 描述

Omron NS Series HMI Improper Neutralization of Input During Web Page Generation

Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.

CVE 解決方案

Omron Corporation has produced update, Version 8.69x for Japan and Version 8.7x for other countries, that mitigates the identified vulnerabilities. The updates for the NS series of HMI terminals can be downloaded at the following locations: NS15 Software Update Version 8.7: http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html NS12 Software Update Version 8.7: http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html NS10 Software Update Version 8.7: http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html NS8 Software Update Version 8.7: http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html NS5 Software Update Version 8.7: http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html

CVE 資訊

相關弱點

CWE-ID 弱點名稱 來源
CWE-79 Improper Neutralization of Input During Web Page Generation
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

指標

指標 評分 嚴重程度 CVSS 向量 來源
V2 4 AV:N/AC:L/Au:S/C:N/I:P/A:N
V2 3.5 AV:N/AC:M/Au:S/C:N/I:P/A:N nvd@nist.gov

EPSS

EPSS 是一種預測漏洞被利用可能性的評分模型。

EPSS 評分

EPSS 模型產生介於 0 到 1(0% 到 100%)之間的概率分數。分數越高,漏洞被利用的概率越大。

EPSS 百分位數

百分位數用於根據 EPSS 分數對 CVE 進行排名。例如,EPSS 評分在第 95 百分位的 CVE 比 95% 的其他 CVE 更有可能被利用。因此,百分位數用於比較某 CVE 的 EPSS 分數與其他 CVE 的相對位置。

相關產品

設定 0

Omron>>Ns_series_system_program_firmware >> Version 8.1

Omron>>Ns_series_system_program_firmware >> Version 8.68

Omron>>Ns10_hmi_terminal >> Version -

Omron>>Ns12_hmi_terminal >> Version -

Omron>>Ns15_hmi_terminal >> Version -

Omron>>Ns5_hmi_terminal >> Version -

Omron>>Ns8_hmi_terminal >> Version -

參考資料

http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01
Tags : Third Party Advisory, US Government Resource