CVE-2014-9188:詳細資料

CVE-2014-9188

19.57%V4
2014-12-27
15h00 +00:00
Command InjectionOverflow
A03-Injection
Network
2025-07-24
22h39 +00:00
指定 CVE 通知
掌握特定 CVE 的任何變更。
管理通知

CVE 描述

Schneider Electric ProClima Command Injection

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.

CVE 解決方案

Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric’s web site at the following location: http://www.schneider-electric.com/ww/en/download/document/ProClima_software For further information on these vulnerabilities, please see Schneider Electric’s security notification (SEVD 2014-344-01) at Schneider Electric’s cybersecurity web page: http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page%20

CVE 資訊

相關弱點

CWE-ID 弱點名稱 來源
CWE-77 Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary.

指標

指標 評分 嚴重程度 CVSS 向量 來源
V2 10 AV:N/AC:L/Au:N/C:C/I:C/A:C
V2 9 AV:N/AC:L/Au:N/C:C/I:P/A:P nvd@nist.gov

EPSS

EPSS 是一種預測漏洞被利用可能性的評分模型。

EPSS 評分

EPSS 模型產生介於 0 到 1(0% 到 100%)之間的概率分數。分數越高,漏洞被利用的概率越大。

EPSS 百分位數

百分位數用於根據 EPSS 分數對 CVE 進行排名。例如,EPSS 評分在第 95 百分位的 CVE 比 95% 的其他 CVE 更有可能被利用。因此,百分位數用於比較某 CVE 的 EPSS 分數與其他 CVE 的相對位置。

相關產品

設定 0

Schneider_electric>>Proclima >> Version 至(含) 6.0.1

參考資料

https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01
Tags : Patch, Third Party Advisory, US Government Resource