CVE-2025-14858:詳細資料

CVE-2025-14858

0.02%V4
2026-04-07
20h16 +00:00
2026-07-24
23h10 +00:00
指定 CVE 通知
掌握特定 CVE 的任何變更。
管理通知

CVE 描述

The Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device's SPI interface.

CVE 資訊

相關弱點

CWE-ID 弱點名稱 來源
CWE-226 Sensitive Information in Resource Not Removed Before Reuse
The product releases a resource such as memory or a file so that it can be made available for reuse, but it does not clear or "zeroize" the information contained in the resource before the product performs a critical state transition or makes the resource available for reuse by other entities.

EPSS

EPSS 是一種預測漏洞被利用可能性的評分模型。

EPSS 評分

EPSS 模型產生介於 0 到 1(0% 到 100%)之間的概率分數。分數越高,漏洞被利用的概率越大。

EPSS 百分位數

百分位數用於根據 EPSS 分數對 CVE 進行排名。例如,EPSS 評分在第 95 百分位的 CVE 比 95% 的其他 CVE 更有可能被利用。因此,百分位數用於比較某 CVE 的 EPSS 分數與其他 CVE 的相對位置。

參考資料