Mitsubishi Electric R16MTCPU

CPE Details

Mitsubishi Electric R16MTCPU
-
2020-12-02
11h30 +00:00
2021-05-11
13h37 +00:00
Alerte pour un CPE
Stay informed of any changes for a specific CPE.
Notifications manage

CPE Name: cpe:2.3:h:mitsubishielectric:r16mtcpu:-:*:*:*:*:*:*:*

Informations

Vendor

mitsubishielectric

Product

r16mtcpu

Version

-

Related CVE

Open and find in CVE List

CVE ID Published Description Score Severity
CVE-2020-16850 2020-11-30 20h34 +00:00 Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to restore production, and the device state is lost. This is related to R04CPU, RJ71GF11-T2, R04CPU, and RJ71GF11-T2.
7.5
High