Tenda F1203 Firmware 2.0.1.6

CPE Details

Tenda F1203 Firmware 2.0.1.6
2.0.1.6
2023-09-29
01h57 +00:00
2023-09-29
01h57 +00:00
Alerte pour un CPE
Stay informed of any changes for a specific CPE.
Notifications manage

CPE Name: cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*

Informations

Vendor

tenda

Product

f1203_firmware

Version

2.0.1.6

Related CVE

Open and find in CVE List

CVE ID Published Description Score Severity
CVE-2024-32310 2024-04-16 22h00 +00:00 Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.
8
High
CVE-2024-32312 2024-04-16 22h00 +00:00 Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.
5.7
Medium
CVE-2024-2979 2024-03-27 14h00 +00:00 A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-2978 2024-03-27 14h00 +00:00 A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-2977 2024-03-27 13h31 +00:00 A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-2976 2024-03-27 13h31 +00:00 A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2023-38930 2023-08-06 22h00 +00:00 Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
9.8
Critical
CVE-2023-38931 2023-08-06 22h00 +00:00 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
9.8
Critical
CVE-2023-38933 2023-08-06 22h00 +00:00 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
9.8
Critical
CVE-2023-38934 2023-08-06 22h00 +00:00 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
9.8
Critical
CVE-2023-38936 2023-08-06 22h00 +00:00 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
9.8
Critical
CVE-2023-38940 2023-08-06 22h00 +00:00 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
9.8
Critical
CVE-2022-46530 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mac parameter at /goform/GetParentControlInfo.
7.5
High
CVE-2022-46531 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/addWifiMacFilter.
7.5
High
CVE-2022-46532 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceMac parameter at /goform/addWifiMacFilter.
7.5
High
CVE-2022-46533 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeed parameter at /goform/SetClientState.
7.5
High
CVE-2022-46534 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the speed_dir parameter at /goform/SetSpeedWan.
7.5
High
CVE-2022-46535 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/SetClientState.
7.5
High
CVE-2022-46536 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeedUp parameter at /goform/SetClientState.
7.5
High
CVE-2022-46537 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the security parameter at /goform/WifiBasicSet.
7.5
High
CVE-2022-46538 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteFacMac.
9.8
Critical
CVE-2022-46539 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the security_5g parameter at /goform/WifiBasicSet.
7.5
High
CVE-2022-46540 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/addressNat.
7.5
High
CVE-2022-46541 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the ssid parameter at /goform/fast_setting_wifi_set.
7.5
High
CVE-2022-46542 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/addressNat.
7.5
High
CVE-2022-46543 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mitInterface parameter at /goform/addressNat.
7.5
High
CVE-2022-46544 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand.
7.5
High
CVE-2022-46545 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting.
7.5
High
CVE-2022-46546 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/RouteStatic.
7.5
High
CVE-2022-46547 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer.
9.8
Critical
CVE-2022-46548 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient.
7.5
High
CVE-2022-46549 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo.
7.5
High
CVE-2022-46550 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the urls parameter at /goform/saveParentControlInfo.
7.5
High
CVE-2022-46551 2022-12-20 00h00 +00:00 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the time parameter at /goform/saveParentControlInfo.
7.5
High