Omron CX-Server 5.0.22

CPE Details

Omron CX-Server 5.0.22
5.0.22
2018-05-21
15h33 +00:00
2021-04-23
15h01 +00:00
Alerte pour un CPE
Stay informed of any changes for a specific CPE.
Notifications manage

CPE Name: cpe:2.3:a:omron:cx-server:5.0.22:*:*:*:*:*:*:*

Informations

Vendor

omron

Product

cx-server

Version

5.0.22

Related CVE

Open and find in CVE List

CVE ID Published Description Score Severity
CVE-2021-27413 2021-05-13 16h56 +00:00 Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
7.8
High
CVE-2020-27257 2021-02-09 14h10 +00:00 This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices.
7.8
High
CVE-2020-27261 2021-02-09 14h09 +00:00 The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
8.8
High
CVE-2020-27259 2021-02-09 14h09 +00:00 The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code.
8.8
High
CVE-2018-18989 2018-12-04 21h00 +00:00 In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
7.8
High
CVE-2018-18993 2018-12-04 21h00 +00:00 Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.
7.8
High
CVE-2018-7514 2018-04-17 19h00 +00:00 Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow.
7.8
High
CVE-2018-7530 2018-04-17 19h00 +00:00 Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may allow the pointer to call an incorrect object resulting in an access of resource using incompatible type condition.
7.8
High
CVE-2018-8834 2018-04-17 19h00 +00:00 Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow.
7.8
High