Tenda F1202

CPE Details

Tenda F1202
-
2023-07-13
15h46 +00:00
2023-08-18
17h32 +00:00
Alerte pour un CPE
Stay informed of any changes for a specific CPE.
Notifications manage

CPE Name: cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*

Informations

Vendor

tenda

Product

f1202

Version

-

Related CVE

Open and find in CVE List

CVE ID Published Description Score Severity
CVE-2024-3878 2024-04-16 18h31 +00:00 A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-3877 2024-04-16 18h31 +00:00 A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-3876 2024-04-16 18h00 +00:00 A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-3875 2024-04-16 18h00 +00:00 A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
High
CVE-2024-30635 2024-03-29 00h00 +00:00 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability located in the funcpara1 parameter in the formSetCfm function.
9.8
Critical
CVE-2024-30634 2024-03-28 23h00 +00:00 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function.
8
High
CVE-2024-30636 2024-03-28 23h00 +00:00 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function.
6.5
Medium
CVE-2024-30637 2024-03-28 23h00 +00:00 Tenda F1202 v1.2.0.20(408) has a command injection vulnerablility in the formWriteFacMac function in the mac parameter.
8.8
High
CVE-2024-30638 2024-03-28 23h00 +00:00 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function.
4.3
Medium
CVE-2024-30639 2024-03-28 23h00 +00:00 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability in the page parameter of fromAddressNat function.
6.5
Medium
CVE-2023-38932 2023-08-06 22h00 +00:00 Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.
9.8
Critical
CVE-2023-38938 2023-08-06 22h00 +00:00 Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im.
9.8
Critical
CVE-2023-38939 2023-08-06 22h00 +00:00 Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
9.8
Critical
CVE-2023-37714 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
9.8
Critical
CVE-2023-37715 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.
9.8
Critical
CVE-2023-37716 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
9.8
Critical
CVE-2023-37717 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
9.8
Critical
CVE-2023-37718 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.
9.8
Critical
CVE-2023-37719 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.
9.8
Critical
CVE-2023-37721 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter.
9.8
Critical
CVE-2023-37722 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter.
9.8
Critical
CVE-2023-37723 2023-07-13 22h00 +00:00 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
9.8
Critical
CVE-2023-37712 2023-07-09 22h00 +00:00 Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
9.8
Critical