Mitsubishielectric Fx3u-enet Firmware -

CPE Details

Mitsubishielectric Fx3u-enet Firmware -
-
2020-12-22
15h32 +00:00
2020-12-22
15h32 +00:00
Alerte pour un CPE
Restez informé de toutes modifications pour un CPE spécifique.
Gestion des notifications

CPE Name: cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:-:*:*:*:*:*:*:*

Informations

Vendor

mitsubishielectric

Product

fx3u-enet_firmware

Version

-

Related CVE

Open and find in CVE List

CVE ID Publié Description Score Gravité
CVE-2023-4562 2023-10-13 01h26 +00:00 Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.
9.1
Critique
CVE-2021-20613 2022-01-14 18h04 +00:00 Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
7.5
Haute
CVE-2021-20612 2022-01-14 18h04 +00:00 Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
7.5
Haute
CVE-2021-20596 2021-07-22 09h02 +00:00 NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery.
7.5
Haute
CVE-2020-16226 2020-10-05 17h19 +00:00 Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
9.8
Critique