Tenda AC8

CPE Details

Tenda AC8
-
2023-06-06
16h29 +00:00
2023-08-18
17h32 +00:00
Alerte pour un CPE
Restez informé de toutes modifications pour un CPE spécifique.
Gestion des notifications

CPE Name: cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*

Informations

Vendor

tenda

Product

ac8

Version

-

Related CVE

Open and find in CVE List

CVE ID Publié Description Score Gravité
CVE-2025-29100 2025-03-24 00h00 +00:00 Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
9.8
Critique
CVE-2025-29118 2025-03-19 00h00 +00:00 Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
6.5
Moyen
CVE-2025-25510 2025-02-21 00h00 +00:00 Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function.
6.5
Moyen
CVE-2024-11745 2024-11-26 21h00 +00:00 A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
8.7
Haute
CVE-2024-4066 2024-04-23 21h00 +00:00 A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
Haute
CVE-2024-4065 2024-04-23 20h00 +00:00 A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
Haute
CVE-2024-4064 2024-04-23 20h00 +00:00 A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
Haute
CVE-2023-33669 2023-06-01 22h00 +00:00 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
9.8
Critique
CVE-2023-33670 2023-06-01 22h00 +00:00 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
9.8
Critique
CVE-2023-33671 2023-06-01 22h00 +00:00 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
9.8
Critique
CVE-2023-33672 2023-06-01 22h00 +00:00 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
7.5
Haute
CVE-2023-33673 2023-06-01 22h00 +00:00 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
9.8
Critique
CVE-2023-33675 2023-06-01 22h00 +00:00 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
9.8
Critique