Tenda Ac500 Firmware 2.0.1.9(1307)

CPE Details

Tenda Ac500 Firmware 2.0.1.9(1307)
2.0.1.9\(1307\)
2023-09-29
01h57 +00:00
2023-09-29
01h57 +00:00
Alerte pour un CPE
Restez informé de toutes modifications pour un CPE spécifique.
Gestion des notifications

CPE Name: cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\(1307\):*:*:*:*:*:*:*

Informations

Vendor

tenda

Product

ac500_firmware

Version

2.0.1.9\(1307\)

Related CVE

Open and find in CVE List

CVE ID Publié Description Score Gravité
CVE-2024-10280 2024-10-23 13h31 +00:00 A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
7.1
Haute
CVE-2024-3910 2024-04-17 12h00 +00:00 A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
Haute
CVE-2024-3909 2024-04-17 11h31 +00:00 A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
9.8
Critique
CVE-2024-3908 2024-04-17 11h31 +00:00 A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
9.8
Critique
CVE-2024-3907 2024-04-17 11h00 +00:00 A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
9.8
Critique
CVE-2024-3906 2024-04-17 10h31 +00:00 A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
Haute
CVE-2024-3905 2024-04-17 10h31 +00:00 A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
8.8
Haute
CVE-2024-32314 2024-04-16 22h00 +00:00 Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
3.8
Bas
CVE-2024-32316 2024-04-16 22h00 +00:00 Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
6.5
Moyen
CVE-2024-32318 2024-04-16 22h00 +00:00 Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
9.8
Critique
CVE-2024-32320 2024-04-16 22h00 +00:00 Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
5.9
Moyen
CVE-2023-25233 2023-02-27 00h00 +00:00 Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface.
9.8
Critique
CVE-2023-25234 2023-02-27 00h00 +00:00 Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface.
9.8
Critique
CVE-2023-25235 2023-02-27 00h00 +00:00 Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid.
7.5
Haute